For Kinematic Viscosity of Transparent and Opaque Liquids
ASTM D445, ISO 3104, IP 71, ASTM D446, ISO 3105
CAV® 4.2 is a dual-bath, benchtop viscometer with two 14-position sample handlers for unattended D445 processing. Each of the Ubbelohde-style tubes (one per bath) covers a 100-fold viscosity range between 0.5 mm²/s (cSt) and 10,000 mm²/s (cSt) from 15 °C to 150 °C (with available options).
Common Applications
- Formulated oil analysis
- Hydraulic oil analysis
- Additive analysis
- Marine fuel testing
- Base stock analysis
- Light and heavy fuel testing
- Waxes/paraffin
- Crude oil testing
- Glycols
Features & Benefits
D445 precision in a modern, dependable design
- Temperature range: ambient to 100 °C (15 °C to 150 °C with available bath options)
- Viscosity range: 0.5 mm2/s (cSt) to 10,000 mm2/s (cSt)* in 100-fold increments (easily covering the range of 5 separate manual glass viscometers)
- Dual, independent modular baths provide easy maintenance access and simultaneous testing at two different temperatures
- Two independent, fully-accessible sample handlers ensure reliable, unattended processing of up to 24 determinations per hour
- Optional environmentally-friendly Peltier cooling
Fully self-contained bench-top unit with flexible connectivity
- Simple, out-of-the-box installation. No external components required
- 35% smaller footprint conserves lab space
- Single unit runs using the on-board computer, without need for an external PC, or a single PC manages up to 4 units using VISCPRO® software
Reduced consumable costs
- ASTM D445/ISO 3105 Ubbelohde-style tube design reduces solvent usage and disposal costs by 50%
- Automated vial washing and drying reduces vial consumption and replaces manual washing
Simplified maintenance and test versatility
- Operators replace tubes in minutes, eliminating the need to schedule related service calls
- Single-point temperature calibration avoids tube recalibration costs and maximizes test flexibility
- Colored status indicator bath lights provide a simple remote indication of operational status
- Multiple pre-defined/user-defined test methods can be run in the same sample tray
- High-throughput, selective zone heating preheats individual samples to any temperature from ambient to 100 °C
- Standard dual-solvent input
* Some upper viscosity measurements may be limited by test temperature and sample type. Fast run (10-fold range) tubes are also available.
VISCOMETER TUBES
Standard Tubes | Fast Run Tubes | |||
---|---|---|---|---|
KV Range in mm²/s (cSt) |
Part Number | KV Range in mm²/s (cSt) |
Part Number | |
0.5-50 | 12.0581 | 0.5-5 | 12.0304 | |
1-100 | 12.0287 | 1-10 | 12.0305 | |
2-200 | 12.0288 | 2-20 | 12.0306 | |
3-300 | 12.0289 | 3-30 | 12.0307 | |
4-400 | 12.0290 | 4-40 | 12.0308 | |
5-500 | 12.0291 | 5-50 | 12.0309 | |
6-600 | 12.0292 | 6-60 | 12.0310 | |
7-700 | 12.0578 | —— | —— | |
8-800 | 12.0293 | 8-80 | 12.0311 | |
10-1000 | 12.0294 | 10-100 | 12.0312 | |
15-1500 | 12.0302 | 15-150 | 12.0313 | |
20-2000 | 12.0295 | 20-200 | 12.0314 | |
30-3000 | 12.0296 | 30-300 | 12.0315 | |
40-4000 | 12.0297 | 40-400 | 12.0316 | |
50-5000 | 12.0298 | 50-500 | 12.0317 | |
60-6000 | 12.0303 | 60-600 | 12.0318 | |
—— | —— | 80-800 | 12.0319 | |
100-10000 | 12.0299 | 100-1000 | 12.0532 |
Options
Factory installed options (see NOTE) must be specified when ordering. Part numbers are listed below for field installable options. Field installation must be performed by factory-trained personnel (unless indicated by an asterisk *). Field installation costs are not included.
Note: A third solvent input, integrated high temperature baths (left or right) and additional temperature calibration (for each temperature beyond the first) are also available at the time of ordering.
Description | Part # |
---|---|
Sample pre-heat assembly for glass vials (left/right) | 68.0538/68.0540 |
Sample pre-heat assembly for use with metal sleeves (left/right) | 68.0537/68.0539 |
Sample carousel safely cover* | 68.0299 |
Integrated thermoelectric bath cooling (per bath) | 68.0541 |
External heated waste drain lines w/ external power supply* | 68.3112 |
Laser printer* | 93.6005 |